Energy Code Testing

Duct Leakage Test

Verify duct system performance and ensure compliance with energy code standards for new construction.

What Is a Duct Leakage Test?

A duct leakage test measures how much conditioned air escapes from the duct system before reaching its intended destination. Using a calibrated fan and pressure gauges, we pressurize the duct system and measure the airflow needed to maintain that pressure — revealing exactly how much air is leaking out.

Why It Matters

Code Compliance

Required by the 2015 IECC (Section R403.3.4) for new residential construction in Colorado.

System Efficiency

Leaky ducts can waste 20–30% of the energy used to heat and cool your home.

Equipment Longevity

Properly sealed ducts reduce strain on HVAC equipment, extending its operational lifespan.

Comfort & Balance

Sealed ducts deliver the right amount of conditioned air to every room as designed.

How It Works

1

System Preparation

All supply and return registers are sealed with temporary covers. The air handler is isolated from the duct system.

2

Fan Connection

A calibrated duct blaster fan is connected to the duct system through a register opening.

3

Pressurization

The duct system is pressurized to 25 Pascals and the airflow required to maintain that pressure is measured.

4

Results & Report

Leakage is calculated as a percentage of conditioned floor area and compared against the IECC code limit.

Schedule Your Duct Leakage Test

Keep your project on track with fast, accurate duct leakage testing from our certified team.